On the Transmigration of Souls Tech Specs

April 17, 2010

NOTES

There are two possible versions for playback presentation.

There are five playback cues total.

PLAYBACK FOR SOULS

Version 1 (recommended): consists of a computer driven six-channel surround sound-style presentation. The presenter will be required to obtain all of the equipment+software for this presentation. Boosey will supply a data CD and technical support needed to get the work up and running. The presenter will be required to hire a qualified sound designer/engineer to perform the tasks of various specific setup/performance needs, and who has the ability to read music for the five playback “cues” in the score.

Version 2 (alternate): consists of a two-track mix of the surround playback. It should be broadcast through a high-quality stereo house sound system, two-channels only. The presenter will still be required to hire a sound engineer who reads music for the five playback “cues”. Boosey&Hawkes will supply an audio CD containing the five playback cues.

SURROUND SOUND DETAILS

Six zone surround system (with recommended speaker types) for a 1000 seat house, with no balcony – please adjust if you have balconies and larger seating layout:

Zone 1 + 2 is a Main PA system located onstage with the orchestra. A high-quality stereo house PA running in stereo. Zone 1 = house left,

Zone 2 = house right. One Meyer Sound CQ-1P per side. Subs not needed.

Zone 3 + 4 is a mid-audience surround — Z3=houseleft, Z4=houseright. Speakers should be rigged close to auditorium walls, above audience heads (approx. 6ft above). One Meyer UPA-1P per side.

Zone 5 + 6 is a rear-audience surround — Z5=houseleft, Z6=houseright. Speakers should be rigged close to auditorium walls, above audience heads (approx. 6ft above). One Meyer UPA-1P per side.

Speakers should be placed to have maximum coverage for the audience without cabinets being too close to individual seats – a basic “wash” coverage for each zone is needed, on all seating levels.

PLAYBACK CUES

1 – starts before bar 1
2 – bar 80
3 – bar 120
4 – bar 161
5 – bar 440

GENERAL NOTES

Please contact John Adams’ Sound Designer, Mark Grey (mhgrey@earthlink.net), once the sound engineer has been chosen for the production. Mr. Grey will help work with the production sound engineer to make sure presentation is in good standing.